Manitowoc E12
Curtain switch fault - open for 12+ hours
What does Manitowoc E12 mean?
E12 logs when the water splash curtain switch remains in the open position (curtain absent or switch not actuated) for more than 12 continuous hours. This is distinct from E11 — E12 is specifically a sustained-duration curtain absence fault, indicating the machine has been running without curtain detection for an extended period, or the curtain switch has failed in the open state.
Symptoms
- E12 appears in the event log after extended machine operation.
- Water splash curtain is missing from the ice machine.
- Curtain switch LED on the control board is dark during normal operation.
- Machine may continue to run but logs the fault after 12 hours of continuous curtain-absent detection.
Common causes
- Water splash curtain was removed during cleaning and not reinstalled.
- Curtain fell out of its track during normal machine operation.
- Curtain position switch failed in the open (non-actuated) position.
- Broken curtain tab preventing switch actuation even with the curtain installed.
- Wiring failure causing the control board to see the switch as perpetually open.
Diagnostic steps
- 01
Check if curtain is installed
Open the ice machine and confirm the water splash curtain is present and seated correctly in its track. If missing, reinstall it immediately — the curtain is essential for safe water system operation.
- 02
Inspect the curtain tab and switch
With the curtain installed, verify its actuating tab is intact and that pressing it against the curtain switch causes the corresponding LED on the control board to illuminate. Replace the curtain if the tab is broken.
- 03
Test the curtain switch with a multimeter
Disconnect the switch connector and measure continuity across the switch terminals when the switch button is pressed. An open reading when actuated confirms switch failure — replace the switch.
- 04
Inspect the wiring harness
Trace the curtain switch wiring from the switch body to the control board connector. Look for chafed insulation, corrosion on the connector pins, or a loose board-side connector.
- 05
Clear the fault and monitor
After correcting the root cause, power-cycle the machine. Confirm the curtain switch LED illuminates on the control board. Monitor the event log to ensure E12 does not recur.
Keep this fix — get it by email with every Manitowoc error code
A clean printable version of this Manitowoc E12 guide + the full Manitowoc code pack (30 codes), straight to your inbox. Free.
When to call a professional
If the curtain and switch are confirmed correct but E12 persists, the control board input circuit may be faulty. Control board diagnosis and replacement require a factory-trained technician to avoid misdiagnosis.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Manitowoc error codes
Long freeze cycle exceeded limit
E02Long harvest cycle exceeded 3.5 minutes
E03Input power loss detected
E04High condenser temperature
E05High pressure control opened (HPCO tripped)
E07Starving TXV or low refrigerant charge
E08TXV fault - flooding or valve issue
E09Evaporator #1 flooding
E10Evaporator #2 flooding (dual circuit)
E11Refrigeration fault or curtain fault
E15Fan cycle control fault / low liquid line temp
E16Remote condenser fault
Sources: www.partstown.com, www.icemachineskc.com, www.easyice.com