Sirman E3
Home search failed — check encoder connection, motor connection, and hopper end-of-stroke magnet (PLD 300-330-350 AUT)
Source: Sirman_15354C2GU2S_user-manual_EN.pdf
What does Sirman E3 mean?
During startup or cycle initialization, the PLD 300-330-350 AUT control attempts to find the home position of the hopper or portioning mechanism. E3 indicates this homing sequence failed — the machine could not confirm the mechanism reached its home/reference position within the expected parameters. The manual points to three specific areas for diagnosis: the encoder connection, the motor connection, and the hopper assembly end-of-stroke magnet.
Symptoms
- Display shows 'E3' during startup or at the beginning of a portioning cycle
- Hopper or portioning mechanism does not complete its homing movement
- Machine may move partially then stop and display E3
- Machine may not move the hopper at all before displaying the error
- Cycle cannot be initiated until the fault is resolved
Common causes
- Encoder connector disconnected, loose, or damaged preventing position feedback
- Motor connector disconnected or poor connection preventing drive output to the hopper motor
- End-of-stroke magnet on the hopper assembly missing, displaced, or demagnetized
- Hall effect sensor or magnetic sensor for home detection misaligned or failed
- Encoder failure or damage causing incorrect or absent position signals
- Motor fault preventing the mechanism from physically reaching the home position
Diagnostic steps
- 01
Inspect and reseat the encoder connection
Power down the PLD 300/330/350 AUT and locate the encoder connector on the hopper drive assembly. Check for loose, damaged, or corroded pins and reseat the connector firmly, ensuring it is fully locked.
- 02
Inspect and reseat the motor connection
Locate the hopper motor electrical connector and check for the same issues — looseness, corrosion, bent pins, or partial disconnection. Reconnect securely and confirm the connector is fully engaged.
- 03
Locate and inspect the end-of-stroke magnet
Find the end-of-stroke magnet on the hopper assembly as referenced in the Sirman manual. Confirm it is present, physically intact, correctly positioned, and has not shifted or fallen out of its mount.
- 04
Check the home position sensor alignment
Confirm the magnetic sensor or Hall effect sensor that detects the end-of-stroke magnet is correctly aligned with the magnet's travel path and has not been moved, bent, or contaminated.
- 05
Power on and retest homing sequence
After inspecting and securing all connections and components, power the machine back on and allow the homing cycle to run, observing whether E3 clears and the hopper reaches its home position successfully.
- 06
Test encoder signal integrity if error persists
If E3 remains after mechanical checks, use a multimeter or scope to verify the encoder is generating valid signals during hopper movement. No signal or erratic signal with the connection secure indicates encoder failure requiring replacement.
Keep this fix — get it by email with every Sirman error code
A clean printable version of this Sirman E3 guide + the full Sirman code pack (12 codes), straight to your inbox. Free.
When to call a professional
Escalate to a licensed Sirman service technician if the end-of-stroke magnet is damaged, the encoder has failed, the motor has an internal fault, or sensor replacement is required. Electrical diagnosis of the encoder feedback loop and motor drive circuit on the PLD 300/330/350 AUT requires qualified personnel to avoid damage to the control board or drive components.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Sirman error codes
Automatic carriage movement does not work because the carriage is not engaged (VA 4000)
FuseFuse for automatic carriage movement is activated; automatic carriage movement does not work (VA 4000)
Make serviceMachine has exceeded 750,000 slices and requires general maintenance (VA 4000)
E1High mechanical load detected — reduce quantity/weight of product loaded (PLD 300-330-350 AUT)
E2Slices value set to 0 with slice counter enabled — set the number of slices (PLD 300-330-350 AUT)
E4Hardware error — check communication between keyboard and power supply (PLD 300-330-350 AUT)
E5Hardware error — check encoder connection (PLD 300-330-350 AUT)
E6Motor overheating detected on Sirman PLD 300-330-350 AUT – power cycle required; power board may need replacement.
E7DC bus voltage too low on Sirman PLD 300-330-350 AUT – check incoming mains supply voltage.
E8DC bus voltage too high on Sirman PLD 300-330-350 AUT – check incoming mains supply voltage.
E9Requested motor speed too high on Sirman PLD 300-330-350 AUT – reduce product quantity or weight loaded.