Quick Answer
Blodgett convection and HydroVection ovens lock out heat and sound an alarm on three faults: ERR1 is a heating-circuit fault (control commanded heat but cavity temperature never rose), ERR7 is a control-board communication failure on the internal data bus, and PROBE (also PROBE OPEN or PROBE SHORT) means the temperature sensor circuit has failed.
Blodgett Troubleshooting Assistant
Get instant AI-powered help for Blodgett fault codes and equipment issues via WhatsApp. Our assistant is trained on official manufacturer documentation — available 24/7 for field technicians.
Co-founder & CTO · Reviewed June 2026
What error codes does Blodgett display?
No heat / heating fault — verify breaker and gas supply, check the igniter or heating elements, inspect control-board relays
Board-to-board communication failure — reseat ribbon cables and harnesses, check for moisture/grease ingress, verify supply voltage
Probe failure (PROBE OPEN = open circuit, PROBE SHORT = short) — ohm the probe against the Blodgett chart and check seating and wiring
Common questions about Blodgett equipment
What other commercial kitchen brands does AskWhiz cover?
AskWhiz also covers troubleshooting for these manufacturers in the same industry:
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call