Navien E407 Error Code
Hotwateroutlet:thermostat Contact Technical Support at 1-800-519-8794. openorsho
Source: npn-199e__navi-npn-199e-english-iom.pdf
What does Navien E407 mean?
E407 indicates the hot water outlet thermistor has reported an open or short circuit condition. The PCB uses this thermistor to monitor delivered water temperature and modulate the burner; when the sensor's resistance is outside the expected range for any water temperature, the control board treats the reading as a fault and shuts the unit down to prevent scalding or damage.
Symptoms
- Unit displays E407 and stops producing hot water.
- Water temperature may be erratic or incorrect just before the error appears.
- Error persists after reset attempts; the thermistor fault is continuous.
- Hot water output cut off completely at the outlet.
Common causes
- Thermistor probe has failed open or short internally.
- Wiring harness connector at the thermistor is corroded, loose, or broken.
- Water leak near the thermistor has caused connector corrosion.
- PCB thermistor input circuit has failed.
Ask the AskWhiz AI about Navien E407
AskWhiz
online
Diagnostic steps
Power down the unit
Switch off power and shut off the cold water supply before accessing internal components. Allow the unit to cool if it has been running.
Locate the hot water outlet thermistor
Consult the wiring diagram in the service manual for your model (NPN-199E section) to identify the hot water outlet thermistor mounting location on the outlet pipe. It typically connects via a two-wire push-on connector.
Inspect the wiring harness and connector
Disconnect the thermistor connector and inspect both the thermistor-side and harness-side pins for corrosion, bent contacts, or broken wire leads. Reseat the connector firmly and check for proper latching.
Test thermistor resistance
With the connector disconnected, measure resistance across the thermistor terminals with a multimeter. Cross-reference the reading against the resistance-temperature table in the service manual. A reading of 0 Ohms (short) or infinite resistance (open) confirms thermistor failure.
Replace the thermistor if defective
Order the OEM replacement thermistor for your Navien model. Install with the same immersion depth and orientation, reconnect the harness, restore power, and run a test cycle to confirm E407 is cleared.
When to call a professional
If replacing the thermistor does not clear E407, the fault may lie in the PCB's thermistor input circuit. PCB replacement on Navien units requires reconfiguring system settings after installation and verifying correct temperature modulation — contact Navien Technical Support at 1-800-519-8794 or dispatch a licensed technician.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Navien documentation and can diagnose this fault code and guide you through the repair in minutes.
Free tier — 10 messages/month, no credit card.
Other Navien Error Codes
Ignitionfailure Ensure that the main gas supply valve is open. E004 Falseflamede
Flameloss Cleantheintakeairfilter.SeetheOperationmanual. ·Ensure that the electr
Overheatingof heatexchanger ·Turn off the system for at least 30 minutes, and th
Exhaustoverheatingthewater Turn off the systemfor at least 30minutes,and then he
Abnormal operation:limit control ContactTechnicalSupportat1-800-519-8794. E047 A
Abnormaloperation:dualventuri Contact Technical Support at 1-800-519-8794. E109
Abnormal air pressure ·Ensurethattheexhaustpipeisfreeofobstructions. ·Clean the
Cold waterinlet1:thermostat Contact Technical Support at 1-800-519-8794. openors
Cold water inlet2:thermostat Contact Technical Support at 1-800-519-8794. openor
Abnormal operation:water ContactTechnicalSupportat1-800-519-8794. adjustment val
Abnormal operation: circulation External: Ensure that all watersupply and return
Abnormaloperation:flowsensor ContactTechnicalSupportat1-800-519-8794. Error Code
Sources: homeinspectioninsider.com, www.waterheaterhub.com, www.tanklesshelp.com