Amana 10 Flashes
Open fuse / no 24V power to the integrated control module — often from a voltage surge.
Source: Amana/Amana_2021F_InstallationGuide_HVAC_EN.pdf
What does Amana 10 Flashes mean?
Ten red flashes indicate an open fuse and no 24-volt power reaching the integrated control module, and the furnace is not operating. A high voltage surge can blow off the fuse, cutting low-voltage power to the control so it can no longer run the furnace until the fuse is replaced.
Symptoms
- Furnace not operating
- Integrated control module diagnostic LED flashes ten red flashes
- No 24-volt power at the control module
- Control fuse is open
Common causes
- Open fuse on the integrated control module
- No 24V power to the integrated control module
- High voltage surge that blows off the fuse
Diagnostic steps
- 01
Replace the fuse
Replace the open fuse to restore 24-volt power to the integrated control module.
- 02
Look for a surge source
Determine whether a high voltage surge blew the fuse so the replacement does not immediately fail again.
- 03
Confirm 24V is restored
Verify the control module receives 24-volt power and resumes normal operation after the fuse is replaced.
- 04
Power off before servicing
Verify the line voltage supply is turned off before proceeding with corrections.
Keep this fix — get it by email with every Amana error code
A clean printable version of this Amana 10 Flashes guide + the full Amana code pack (13 codes), straight to your inbox. Free.
When to call a professional
A fuse that blows once may only need replacing, but a repeatedly opening fuse points to a wiring short or surge that needs professional diagnosis. If the ten-flash code returns after replacing the fuse, or if you cannot safely verify line and low-voltage power, call a qualified servicer. Always confirm the line voltage supply is off before working inside the control area.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Amana error codes
System lockout from too many failed ignition retries — the furnace could not establish or hold flame.
2 FlashesPressure switch circuit is closed when it should be open — the induced draft blower is not operating.
3 FlashesPressure switch circuit is not closing while the induced draft blower runs — restricted airflow or a faulty switch.
4 FlashesPrimary or auxiliary limit circuit is open — the furnace is overheating from insufficient airflow.
5 FlashesFlame sensed with no call for heat — a short to ground in the flame sense circuit.
6 FlashesRollout limit open or the integrated control module fuse is blown — possible flame rollout.
7 FlashesFlame sense microamp signal is low — a coated, oxidized, or misaligned flame sensor.
8 FlashesIgniter relay fault — wiring, igniter, grounding, or control module problem.
9 FlashesTwinning fault — twinned furnaces are not wired or relayed together correctly.
11 FlashesIgniter open — broken igniter, bad wiring, or poor grounding.
12 FlashesInducer relay fault — inducer wiring, blockage, grounding, or control module problem.
Continuous Rapid FlashReversed polarity of 115V or 24V power to the furnace or control module.
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call