Amana 2 Flashes
Pressure switch circuit is closed when it should be open — the induced draft blower is not operating.
Source: Amana/Amana_2021F_InstallationGuide_HVAC_EN.pdf
What does Amana 2 Flashes mean?
Two red flashes indicate the pressure switch circuit is closed at a time the control expects it to be open, while the induced draft blower is not running. The control reads this contradiction as a fault, typically because the pressure switch contacts are stuck closed or there is a short in the pressure switch circuit.
Symptoms
- Furnace fails to operate
- Integrated control module diagnostic LED flashes two red flashes
- Induced draft blower is not running
- Pressure switch circuit reads closed during standby
Common causes
- Induced draft blower pressure switch contacts sticking closed
- Shorts in the pressure switch circuit
- Induced draft blower not operating
Diagnostic steps
- 01
Replace the pressure switch
Replace the induced draft blower pressure switch with the proper replacement part if its contacts are stuck closed.
- 02
Repair the circuit short
Locate and repair any short in the pressure switch circuit that holds the contacts closed.
- 03
Verify induced draft blower operation
Confirm whether the induced draft blower is running, since the fault appears when the blower is off but the switch reads closed.
- 04
Power off before servicing
Turn power off prior to repair before handling the pressure switch or its wiring.
Keep this fix — get it by email with every Amana error code
A clean printable version of this Amana 2 Flashes guide + the full Amana code pack (13 codes), straight to your inbox. Free.
When to call a professional
This fault involves diagnosing a stuck pressure switch and tracing shorts in low-voltage circuits while the furnace is de-energized. If you are not comfortable testing pressure switch contacts, locating a circuit short, or sourcing the correct replacement part, have a qualified servicer perform the repair. Always turn power off prior to working on the switch or wiring.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Amana error codes
System lockout from too many failed ignition retries — the furnace could not establish or hold flame.
3 FlashesPressure switch circuit is not closing while the induced draft blower runs — restricted airflow or a faulty switch.
4 FlashesPrimary or auxiliary limit circuit is open — the furnace is overheating from insufficient airflow.
5 FlashesFlame sensed with no call for heat — a short to ground in the flame sense circuit.
6 FlashesRollout limit open or the integrated control module fuse is blown — possible flame rollout.
7 FlashesFlame sense microamp signal is low — a coated, oxidized, or misaligned flame sensor.
8 FlashesIgniter relay fault — wiring, igniter, grounding, or control module problem.
9 FlashesTwinning fault — twinned furnaces are not wired or relayed together correctly.
10 FlashesOpen fuse / no 24V power to the integrated control module — often from a voltage surge.
11 FlashesIgniter open — broken igniter, bad wiring, or poor grounding.
12 FlashesInducer relay fault — inducer wiring, blockage, grounding, or control module problem.
Continuous Rapid FlashReversed polarity of 115V or 24V power to the furnace or control module.