What error codes does Coreco display?
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
Immediate or delayed alarm from the multifunction digital input (external alarm)
Open-door alarm from the door-switch digital input
Low-temperature alarm — measured temperature below set point by more than parameter AL
High-temperature alarm — measured temperature above set point by more than parameter AH
Unit parameter reading (data) error — saved configuration data error
Operating parameter reading (data) error — manual reset
Defrost ended by timeout — last defrost stopped on maximum duration, not on temperature
Defrost running — status message shown during a defrost cycle (not an alarm)
Dirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)
Internal clock (RTC) alarm — clock fault; reset by setting the time
Dixell XW controller — room (thermostat) probe failure
Dixell XW controller — evaporator probe failure
Dixell XW controller — third (configurable/display) probe failure
Dixell XW controller — fourth probe failure
Dixell XW controller — high-temperature alarm
Dixell XW controller — low-temperature alarm
Dixell XW controller — condenser high-temperature alarm
Dixell XW controller — condenser low-temperature alarm
Dixell XW controller — door-open alarm
Dixell XW controller — external alarm (digital input)
Dixell XW controller — serious external / pressure-switch alarm
Dixell XW controller — real-time-clock alarm (RTC models)
Dixell XW controller — real-time-clock board failure (RTC models)
Dixell XW controller — no parameter / probe not enabled (display message)
Dixell XW controller — keyboard locked (display message)
Carel KDT-Touch controller — Keypad-to-power-board communication error
Carel KDT-Touch controller — On an RTX-RTN-RTD600 (/V) family power board, the E7 keypad-communicat
Carel RTN400 controller — Probe Pb3 faulty (measured values outside operating range or probe fau
Carel RTN400 controller — Probe Pb4 faulty (measured values outside operating range or probe fau
Carel RTN400 controller — Probe Pb5 faulty (measured values outside operating range or probe fau
Carel RTN400 controller — LINK2 probe faulty (measured values outside operating range or probe f
Carel RTN400 controller — VIRTUAL probe faulty (measured values outside operating range or probe
Carel RTN400 controller — HIGH temperature alarm 1
Carel RTN400 controller — LOW temperature alarm 1
Carel RTN400 controller — HIGH temperature alarm 2
Carel RTN400 controller — LOW temperature alarm 2
Carel RTN400 controller — Door-open alarm
Carel RTN400 controller — End-defrost-by-timeout alarm
Carel RTN400 controller — Preheat alarm
Carel RTN400 controller — Clock Alarm
Carel RTN400 controller — HIGH voltage alarm
Carel RTN400 controller — LOW voltage alarm
Carel RTN400 controller — General pressure switch alarm (n < PEn, Auto Reset)
Carel RTN400 controller — Minimum pressure switch alarm (n < PEn, Auto Reset)
Carel RTN400 controller — Maximum pressure switch alarm (n < PEn, Auto Reset)
Carel RTN400 controller — General pressure switch alarm (n = PEn, Manual Reset)
Common questions about Coreco equipment
What other refrigeration brands does AskWhiz cover?
AskWhiz also covers troubleshooting for these manufacturers in the same industry:
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call