Coreco error codes, decoded.
Look up any Coreco fault code below. Each one is grounded in Coreco's own service documentation — the meaning, the symptoms, the causes, and the steps to clear it.
Co-founder & CEO · Reviewed July 2026
Coreco sits in our Refrigeration coverage. Every page here is transcribed from the manufacturer's manuals, not scraped from forums.
What error codes does Coreco display?
Tap a code for the full breakdown — meaning, symptoms, causes, and fix steps.
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
E1Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
E2Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
IAImmediate or delayed alarm from the multifunction digital input (external alarm)
dOrOpen-door alarm from the door-switch digital input
LOLow-temperature alarm — measured temperature below set point by more than parameter AL
HIHigh-temperature alarm — measured temperature above set point by more than parameter AH
EEUnit parameter reading (data) error — saved configuration data error
EFOperating parameter reading (data) error — manual reset
EdDefrost ended by timeout — last defrost stopped on maximum duration, not on temperature
dFDefrost running — status message shown during a defrost cycle (not an alarm)
CHtDirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)
EtCInternal clock (RTC) alarm — clock fault; reset by setting the time
P1Dixell XW controller — room (thermostat) probe failure
P2Dixell XW controller — evaporator probe failure
P3Dixell XW controller — third (configurable/display) probe failure
P4Dixell XW controller — fourth probe failure
HADixell XW controller — high-temperature alarm
LADixell XW controller — low-temperature alarm
HA2Dixell XW controller — condenser high-temperature alarm
LA2Dixell XW controller — condenser low-temperature alarm
dADixell XW controller — door-open alarm
EADixell XW controller — external alarm (digital input)
CADixell XW controller — serious external / pressure-switch alarm
rtCDixell XW controller — real-time-clock alarm (RTC models)
rtFDixell XW controller — real-time-clock board failure (RTC models)
noPDixell XW controller — no parameter / probe not enabled (display message)
LOCDixell XW controller — keyboard locked (display message)
E7Carel KDT-Touch controller — Keypad-to-power-board communication error
Pb7Carel KDT-Touch controller — On an RTX-RTN-RTD600 (/V) family power board, the E7 keypad-communicat
E3Carel RTN400 controller — Probe Pb3 faulty (measured values outside operating range or probe fau
E4Carel RTN400 controller — Probe Pb4 faulty (measured values outside operating range or probe fau
E5Carel RTN400 controller — Probe Pb5 faulty (measured values outside operating range or probe fau
ELCarel RTN400 controller — LINK2 probe faulty (measured values outside operating range or probe f
EiCarel RTN400 controller — VIRTUAL probe faulty (measured values outside operating range or probe
AH1Carel RTN400 controller — HIGH temperature alarm 1
AL1Carel RTN400 controller — LOW temperature alarm 1
AH2Carel RTN400 controller — HIGH temperature alarm 2
AL2Carel RTN400 controller — LOW temperature alarm 2
OPdCarel RTN400 controller — Door-open alarm
Ad2Carel RTN400 controller — End-defrost-by-timeout alarm
PrrCarel RTN400 controller — Preheat alarm
E10Carel RTN400 controller — Clock Alarm
HiPCarel RTN400 controller — HIGH voltage alarm
LoPCarel RTN400 controller — LOW voltage alarm
nPACarel RTN400 controller — General pressure switch alarm (n < PEn, Auto Reset)
LPACarel RTN400 controller — Minimum pressure switch alarm (n < PEn, Auto Reset)
HPACarel RTN400 controller — Maximum pressure switch alarm (n < PEn, Auto Reset)
PACarel RTN400 controller — General pressure switch alarm (n = PEn, Manual Reset)