Tempstar 5 Flashes
Pressure Switch Fault
Source: hvac/tempstar/d0a17b44__pds448090hgs1c1__icp-pdd4-pds4-series-e-g-iom.pdf
What does Tempstar 5 Flashes mean?
On a Tempstar packaged gas/electric unit, the integrated gas unit controller (IGC) LED flashing five times indicates a pressure switch fault. Per Table 5 of the manual, five flashes is this status code. During the heating sequence the pressure switch must confirm the induced-draft motor is moving sufficient combustion air before the burner sequence is allowed to begin.
Symptoms
- IGC LED flashes five times instead of staying continuously on
- Burner sequence does not start on a call for heat
- Induced-draft motor runs but ignition does not proceed
- No gas heating output
Common causes
- Pressure switch not confirming adequate combustion airflow
- Blocked or restricted flue or combustion air path
- Weak or failing induced-draft motor
- Faulty pressure switch or disconnected hose/wiring
Diagnostic steps
- 01
Confirm the LED code
Remove the control access panel and verify the IGC LED is flashing five times, which Table 5 identifies as a pressure switch fault.
- 02
Check the induced-draft motor
On a call for heat, confirm the induced-draft motor runs its pre-purge; the pressure switch must sense it moving sufficient combustion air before burners light.
- 03
Inspect the flue and combustion air path
Look for blockage or restriction in the flue hood and combustion air openings that would prevent the switch from closing.
- 04
Cycle the call for heat
After clearing any obstruction, break and restore the call for heat so the IGC re-checks the pressure switch and resumes the burner sequence.
Keep this fix — get it by email with every Tempstar error code
A clean printable version of this Tempstar 5 Flashes guide + the full Tempstar code pack (9 codes), straight to your inbox. Free.
When to call a professional
Call a qualified service technician if five flashes persist after the flue and combustion air paths have been checked. Diagnosis involves the induced-draft motor, pressure switch, and venting, which the manual reserves for a qualified technician with proper tools. Combustion and venting faults can produce hazardous conditions, so professional service is warranted when the cause is not obvious.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Tempstar error codes
Limit Switch Fault
2 FlashesFlame Sense Fault
3 FlashesFour Consecutive Limit Switch Faults
4 FlashesIgnition Lockout Fault
6 FlashesStatus code listed in IGC LED table; specific meaning not unambiguously resolvable from the ingested text
7 FlashesRollout Switch Fault
8 FlashesInternal Control Fault
9 FlashesTemporary 1-hour auto reset (internal processor fault)