Follett HI PRESSURE
Refrigeration high-pressure hard error (lock-out above 425 psi)
Source: Follett/TechTown Forum/manuals/FOL-HCC1400A_spm.pdf
What does Follett HI PRESSURE mean?
On the Horizon icemaker, if refrigeration pressure rises above 425 psi, a hard error occurs and the HI PRESS (red) alarm LED illuminates. Because it is a hard error, the machine will not restart even after pressure falls back below the 295 psi reset point; the fault must be cleared with the reset button. This protects the system from continued operation at excessive discharge pressure.
Symptoms
- HI PRESS (red) alarm LED illuminated on the control board.
- Machine shut off and not restarting on its own.
- Pressure does not auto-clear even after dropping below the 295 psi reset point.
- High discharge pressure or hot, restricted condenser airflow.
Common causes
- Refrigeration discharge pressure exceeding 425 psi.
- Dirty or blocked condenser reducing heat rejection (air-cooled).
- Ambient air above the 100 F maximum or restricted intake and exhaust grilles.
- Water-cooled condenser water supply problem or fouling.
- Overcharge or non-condensables in the refrigeration system.
Diagnostic steps
- 01
Confirm the hard error
Verify the HI PRESS LED is lit and that the machine stays off, since this is a hard error that will not self-clear after pressure drops below 295 psi.
- 02
Clean and clear the condenser
On air-cooled models clean the condenser coil and confirm the intake and exhaust grilles provide adequate open area, since restricted heat rejection raises high-side pressure.
- 03
Check the operating environment
Confirm ambient air is within the 50 to 100 F range and the required clearances are present, as out-of-spec ambient drives discharge pressure up.
- 04
Check water-cooled condenser
For water-cooled units verify condenser water flow and the factory-set discharge pressure regulation, since loss of condenser cooling raises high-side pressure.
- 05
Reset after correction
Once the cause is corrected, press the reset button to clear the hard HI PRESSURE error; pressure falling below the reset point alone will not restart the machine.
Keep this fix — get it by email with every Follett error code
A clean printable version of this Follett HI PRESSURE guide + the full Follett code pack (11 codes), straight to your inbox. Free.
When to call a professional
A high-pressure lockout points to the sealed refrigeration system, where the manual requires all service be performed per federal, state and local law and warns that recharging to other than factory specifications voids the warranty. Diagnosing charge, non-condensables or a condenser fault, and any work on the refrigerant circuit, should be done by an EPA-certified Follett-authorized technician. Do not attempt to defeat the high-pressure lockout.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Follett error codes
Auger gearmotor current draw exceeded the limit (soft or hard error)
LO WATERInsufficient or absent water at the reservoir sensors (soft or hard error)
DRAIN CLOGWater detected in the drain pan indicating a blocked or slow drain
SERVICEService required indicator (accompanies amps faults or bushing-check interval)
TIME DELAYNormal restart delay after a full bin or amps time-out
LOW BINBin switch closed, calling for ice (normal run-enable indicator)
DRIP TRAYDrip tray full indicator (7 and 15 Series dispensers)
WATER LEAKInternal leak detected in the dispenser (7 and 15 Series)
PMSix-month periodic maintenance required (7 and 15 Series)
SLEEP CYCLEStandby mode after a full bin and inactivity (7 and 15 Series)