AL-01Krupps

Krupps AL-01

Faulty boiler probe and tank probe — both temperature probes are faulty; heating is disabled

Source: Krupps/Krupps_ADVANCE_ServiceManual_CommercialKitchen.pdf

Want this fix in your inbox? Full AL-01 guide + every Krupps code, printable, free.

What does Krupps AL-01 mean?

On a Krupps dishwasher, AL-01 means both temperature probes — the boiler probe and the tank probe — are faulty at the same time. The control board can no longer read either water temperature, so it disables heating as a safety measure. The display shows 'AL' on the left LEDs with the code on the right LEDs, and the alarm light flashes.

Symptoms

  • ALARM light flashing on the control panel
  • 'AL' message on the left digit LEDs with the alarm code on the right
  • Cycle start button shows red (alarm state)
  • Water is not heating — heating is disabled
  • Dishes come out cold, poorly washed or not sanitised

Common causes

  • Both the boiler and tank temperature probes are faulty
  • Probe connector on the power board disconnected or damaged
  • Wiring to both probes interrupted or shorted

Diagnostic steps

  1. 01

    Note the alarm and request a technician

    The manual instructs the final user to request the intervention of a technician; AL-01 is not a user-resettable condition. Switch the machine off and on — if the alarm returns, service is needed.

  2. 02

    Remove and replace the probe connector

    Technician check 1: remove and replace the probe connector on the power board so both probe signals are read correctly.

  3. 03

    Replace the probes

    Technician check 2: replace the temperature probes, as the manual lists both probes as faulty for this alarm.

  4. 04

    Power-cycle and confirm heating returns

    After repair, turn the dishwasher off and on. Heating should re-enable and the alarm should clear once both probes read correctly.

Keep this fix — get it by email with every Krupps error code

A clean printable version of this Krupps AL-01 guide + the full Krupps code pack (7 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

AL-01 is a board/probe-level fault: the manual tells the end user to request a technician, while the actual checks (replacing the probe connector on the power board and replacing the probes) are reserved for the repair technician. If a power-cycle does not clear it, stop using the machine for sanitising loads and call qualified service — working inside the power board and probe wiring requires a trained technician.

Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.

Open a ticket — free account