Faulty boiler probe — boiler probe not connected, interrupted or shorted; boiler heating disabled
Source: Krupps/Krupps_ADVANCE_ServiceManual_CommercialKitchen.pdf
What does Krupps AL-02 mean?
AL-02 on a Krupps dishwasher indicates a faulty boiler probe: the boiler probe does not seem to be connected — it is interrupted or shorted. As a result, boiler heating is disabled.
Symptoms
- ALARM light flashing on the control panel
- 'AL' on the left digit LEDs with the code on the right
- Cycle start button shows red (alarm state)
- Final rinse water is not hot — boiler heating is disabled
- Poor rinse / sanitising results
Common causes
- Boiler probe not connected to the power board
- Boiler probe wiring interrupted (open circuit)
- Boiler probe shorted
- Loose or damaged probe terminal
Diagnostic steps
- 01
Request a technician
The manual directs the final user to request the intervention of a technician for AL-02; the diagnostic checks are technician-level.
- 02
Check the probe connection on the board
Technician check 1: verify the boiler temperature probe is connected correctly on the power board.
- 03
Check the probe terminal
Technician check 2: verify the boiler probe terminal is connected correctly (no loose or broken contact).
- 04
Replace the probe
Technician check 3: replace the boiler probe if it remains interrupted or shorted after the connection checks.
Keep this fix — get it by email with every Krupps error code
A clean printable version of this Krupps AL-02 guide + the full Krupps code pack (7 codes), straight to your inbox. Free.
When to call a professional
If switching the dishwasher off and on does not clear AL-02, call a service technician. The manual's resolution steps — checking the boiler probe's connection on the power board, checking its terminal, and replacing the probe — all involve work inside the machine's wiring and control board and should be done by qualified service personnel, not the operator.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Krupps error codes
Faulty boiler probe and tank probe — both temperature probes are faulty; heating is disabled
AL-03Faulty tank probe — tank probe not connected, interrupted or shorted
AL-04Tank loading timeout — the tank did not fill within the maximum time foreseen
AL-05Drain timeout — the tank pressure switch did not open at the end of the total drain cycle
AL-06Heating timeout — the dishwasher did not heat the water within the intended maximum time; heating disabled
SALExhausted brine — not enough brine (water and salt) for the resin regeneration of the built-in softener