AL-06Krupps

Krupps AL-06 Error Code

Heating timeout — the dishwasher did not heat the water within the intended maximum time; heating disabled

Source: Krupps/Krupps_ADVANCE_ServiceManual_CommercialKitchen.pdf

What does Krupps AL-06 mean?

AL-06 on a Krupps dishwasher is a heating timeout: the machine did not bring the water up to temperature within the maximum time the control allows, so heating is disabled. This typically points to a power, heating-element or contactor problem. The display shows 'AL' on the left LEDs with AL-06 on the right and the alarm light flashes.

Symptoms

  • ALARM light flashing on the control panel
  • 'AL' on the left digit LEDs with the code on the right
  • Water not reaching temperature — heating disabled
  • Dishes come out cold / not sanitised
  • Cycle start button red (alarm state)

Common causes

  • Three-phase electric plug connected incorrectly
  • Three-phase power fuses blown
  • Tank or boiler resistance power plugs disconnected or damaged
  • Tank resistance or boiler resistance damaged
  • Circuit board RL6 or RL7 relay, or three-phase heating contactor, damaged
  • Tank pressure switch damaged, or a tripped tank/boiler safety thermostat

Ask the AskWhiz AI about Krupps AL-06

AskWhiz bot

AskWhiz

online

Hi — I'm the Commercial Kitchen demo. Ask me anything in this domain.

Diagnostic steps

  1. Request a technician

    The manual directs the final user to request the intervention of a technician for AL-06; the checks below are technician-level because they involve mains power and heating circuits.

  2. Check three-phase supply and fuses

    Technician checks: confirm the three-phase electric plug is connected correctly and that no three-phase power fuses are blown.

  3. Check the heating resistances and plugs

    Technician checks: verify the tank/boiler resistance power plugs are connected and undamaged, and that the tank and boiler resistances themselves are not damaged.

  4. Check relays, contactor, pressure switch and safety thermostats

    Technician checks: inspect the RL6/RL7 board relays and the three-phase heating contactor; check the tank pressure switch; and reset a tripped tank or boiler safety thermostat.

When to call a professional

AL-06 is a heating-circuit fault the manual assigns to a technician. Call qualified service: the checks involve three-phase wiring and fuses, the tank and boiler heating resistances and their plugs, the RL6/RL7 board relays and heating contactor, the pressure switch, and resetting tripped safety thermostats. This is high-voltage, heating-element work that must not be attempted by the operator.