Lainox RTC
Clock error - the device cannot store the date and time of HACCP alarms
Source: Lainox/documents/ZO051BA__manuale-uso__en.pdf
What does Lainox RTC mean?
RTC signals a real-time clock error on the controller. The unit can no longer reliably keep the current date and time, so it cannot stamp HACCP alarm events correctly. The control also energizes its alarm relay when this fault is present. It is shown in the appliance's alarm list as a maintenance condition that needs the clock reset or, if it recurs, service attention.
Symptoms
- RTC alarm message appears in the controller's alarm list.
- Date and time displayed are wrong, lost, or reset.
- HACCP alarm records are not stamped with the correct date and time.
- The alarm relay output is activated.
Common causes
- Date and time were never set or were cleared after a power interruption.
- Depleted or failing clock backup battery on the control board.
- Real-time clock chip or control board fault.
- Prolonged disconnection from power.
Diagnostic steps
- 01
Reset the date and time
Per the manual, set the present day and time again from the real-time clock menu. This is the manufacturer's stated solution for the RTC alarm.
- 02
Confirm the alarm clears
After setting the clock, verify the RTC message no longer appears in the alarm list and that the alarm relay output has reset.
- 03
Watch for recurrence after power-off
If the clock loses time again each time the unit is unplugged or power is interrupted, the onboard clock backup battery is likely depleted and needs replacement.
- 04
Verify HACCP logging resumes
Because RTC errors prevent correct date/time stamping of HACCP alarms, confirm that subsequent alarm events are recorded with the correct timestamp once the clock is fixed.
Keep this fix — get it by email with every Lainox error code
A clean printable version of this Lainox RTC guide + the full Lainox code pack (14 codes), straight to your inbox. Free.
When to call a professional
If resetting the date and time does not clear the RTC alarm, or the clock keeps losing time, an authorised service technician should inspect the control board's backup battery and real-time clock circuit. Because accurate timestamps underpin HACCP food-safety records, do not keep the appliance in HACCP-critical service with an unresolved RTC fault; have it repaired by qualified personnel.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Lainox error codes
Cell (chamber) temperature probe error
EVAPORATOR PROBEEvaporator temperature probe error
ROD PROBERod (core/needle) probe error
HIGH PRESSUREHigh pressure alarm (1ph) / high pressure or compressor thermal alarm (3ph)
DOOR OPENDoor open alarm
HIGH TEMPERATUREMaximum temperature alarm (HACCP)
LOW TEMPERATUREMinimum temperature alarm (HACCP)
CYCLE DURATIONChilling or deep freezing not completed within the maximum duration (HACCP)
POWER FAILUREPower source interruption alarm (HACCP)
SANITISINGSanitising alarm - rod probe insertion not correct
SANITISING DURATIONSanitising alarm not cancelled within the maximum duration of the first phase
ROD INSRod not inserted alarm