Quick Answer
Pitco (Welbilt, sister to Frymaster) builds US commercial fryers — Solstice, SE / SELV / SSH electric, SG14 gas, and SELVRF rack-lift. Solstice and I12 / Touchscreen controllers display E1 / E2 drain and probe faults, E3 / E5 / E8 filter and option faults, F1 / F3 fuse / jumper, HI overtemperature, HEAT failure, and Err 200 drain-sense alerts.
Pitco Troubleshooting Assistant
Get instant AI-powered help for Pitco fault codes and equipment issues via WhatsApp. Our assistant is trained on official manufacturer documentation — available 24/7 for field technicians.
Co-founder & CEO · Reviewed May 2026
What error codes does Pitco display?
Drain valve open — controller blocks heating; rotate handle fully closed, verify vat oil level, and ohm the drain microswitch with the valve closed (continuity expected).
Temperature probe (RTD) open or shorted — reseat the probe connector, ohm at room temperature against the model's resistance table; zero or OL means replace the probe.
Filter / no-filter operation flag on SSH electric — filter-cycle interlock not satisfied; check filter-pan position, drain-pan switch, and the F3 fuse on the filter-circuit branch.
Configuration / wiring mismatch — J11 / J12 230 VAC / 240 VAC option harness or 50 Hz / 60 Hz jumper not matching the unit's nameplate; verify against the service manual schematic.
Basket-lift / 24 V option fault on SE / SELV / SSH — lift drive harness disconnected, missing configuration jumper on non-lift units, or controller input-circuit fault.
F1 fuse / SCB jumper position — selects electric (jumper installed across J18) vs gas (jumper removed, roll-out for gas operation) on SELVRF dual-platform control board.
F3 inline fuse — 2.5 A time-delay ceramic on the low-voltage filter-circuit branch; an open F3 disables the filter / drain-pump logic without affecting the main heating circuit.
Software high-limit (HIGH TMP on Touchscreen) — oil 40 °F over setpoint or 410 °F absolute; cool, press the manual reset pushbutton, check oil level and thermostat.
Burner / element commanded but probe registers no temperature rise within the timeout window; drain switch, gas / electric supply, flame-sensing rod, high-limit, contactor coil.
SELVRF rack-lift drain-not-sensed-closed — fully close drain handle, clean and reseat the drain proximity sensor, ohm the sensor at the closed position before replacement.