Silko Er2
Cell (chamber) probe error on the blast chiller
Source: Silko/Silko_BF030AE-R290_UserManual_CK_ML.pdf
What does Silko Er2 mean?
Er2 is the cell probe error on Silko blast chillers driven by the EWBC1400 controller. It indicates the cell (chamber) probe is not connected properly or has failed. Behaviour depends on the running program: a manual program with the needle probe (parameter P3=1) continues using the needle probe as the cell probe, while a manual program without the needle probe (P3=0) stops; an automatic program stops.
Symptoms
- "Er2" is shown on the controller display.
- A manual program without a needle probe stops unexpectedly.
- An automatic program stops because the chamber temperature cannot be read.
- No buzzer sounds; the alarm is indicated on the display only.
Common causes
- Cell (chamber) probe not connected properly to the appliance.
- Cell probe failure.
- Damaged probe cable or connector.
- Loose connection at the controller probe terminal.
Diagnostic steps
- 01
Check the cell probe connection
Verify the cell (chamber) probe is correctly connected to the appliance and reseat the connector at the controller input.
- 02
Use the needle probe as a fallback
If a manual program is in progress with the needle probe (P3=1), the unit continues using the needle probe as the cell probe, so the cycle can finish while you investigate.
- 03
Inspect the probe and wiring
Check the cell probe and its lead for visible damage that could interrupt the signal to the controller.
- 04
Replace the cell probe
If the connection is correct but Er2 remains, the cell probe has failed and must be replaced per the manual.
- 05
Verify normal operation
After repair, confirm Er2 has cleared and the chamber temperature reads correctly through a full cycle.
Keep this fix — get it by email with every Silko error code
A clean printable version of this Silko Er2 guide + the full Silko code pack (12 codes), straight to your inbox. Free.
When to call a professional
Checking the cell probe connection is straightforward, but probe replacement and controller-side diagnosis need a qualified technician. Always disconnect the appliance from power before opening it. If Er2 persists after the probe is reconnected and replaced, call authorised Silko service to inspect the controller input and wiring harness.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Silko error codes
Needle (core) probe error on the blast chiller
Er3Condenser probe error on the blast chiller
Er4Auxiliary condenser probe error on the blast chiller
dOrDoor open alarm on the blast chiller
PrSPressure switch alarm on the blast chiller
Pr1Chamber sensor error on refrigerated units
Pr2Evaporator sensor error on refrigerated units
PFPower failure (HACCP) alarm on refrigerated units
AHMaximum temperature (HACCP) alarm on refrigerated units
ALMinimum temperature (HACCP) alarm on refrigerated units
IdDoor (micro port input) alarm on refrigerated units
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call