Silko Er4
Auxiliary condenser probe error on the blast chiller
Source: Silko/Silko_BF030AE-R290_UserManual_CK_ML.pdf
What does Silko Er4 mean?
Er4 is the auxiliary condenser probe error on Silko blast chillers with the EWBC1400 controller. It means the auxiliary condenser probe is not connected properly or has failed. The auxiliary probe supports condenser/auxiliary fan management, so the controller cannot use it for that control while the fault is active. The code is shown on the display without a buzzer.
Symptoms
- "Er4" appears on the controller display.
- Auxiliary condenser temperature is not read by the controller.
- Auxiliary fan management that relies on this probe may not function as intended.
- No audible alarm sounds with the fault.
Common causes
- Auxiliary condenser probe not connected properly to the EWBC1400 controller.
- Auxiliary condenser probe failure.
- Damaged auxiliary probe cable or connector.
- Loose connection at the controller input.
Diagnostic steps
- 01
Check the auxiliary probe connection
Confirm the auxiliary condenser probe is correctly connected to the EWBC1400 controller and reseat its connector.
- 02
Inspect the probe and wiring
Examine the auxiliary probe and its lead for visible damage that could break the signal path.
- 03
Replace the auxiliary probe
If the connection is correct but Er4 remains, replace the auxiliary condenser probe as stated in the manual.
- 04
Verify the controller configuration
Confirm the auxiliary probe is enabled in the controller setup so the correct fan/auxiliary outputs respond once the probe is restored.
- 05
Confirm the alarm clears
After repair, check that Er4 no longer appears and auxiliary functions resume normal operation.
Keep this fix — get it by email with every Silko error code
A clean printable version of this Silko Er4 guide + the full Silko code pack (12 codes), straight to your inbox. Free.
When to call a professional
Because the auxiliary probe ties into the controller configuration and the refrigeration compartment, probe replacement and any controller-parameter checks should be handled by a qualified Silko service technician. Disconnect the appliance from the electrical supply before opening it. Call for service if Er4 persists after reconnecting and replacing the probe.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Silko error codes
Needle (core) probe error on the blast chiller
Er2Cell (chamber) probe error on the blast chiller
Er3Condenser probe error on the blast chiller
dOrDoor open alarm on the blast chiller
PrSPressure switch alarm on the blast chiller
Pr1Chamber sensor error on refrigerated units
Pr2Evaporator sensor error on refrigerated units
PFPower failure (HACCP) alarm on refrigerated units
AHMaximum temperature (HACCP) alarm on refrigerated units
ALMinimum temperature (HACCP) alarm on refrigerated units
IdDoor (micro port input) alarm on refrigerated units
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call