Everlasting COH
Condenser overheated signal (high condensation)
Source: Everlasting/User Manuals/Master - Classic - Professional - Roll-in _ Roll-through.pdf
What does Everlasting COH mean?
COH is the condenser-overheated signal, described in the manual as a high-condensation warning. The controller reports it when condensing temperature, read from the condenser probe, reaches the high-condensation signalling threshold (parameter C6, defaulting to 60°C). It is an early warning that the condenser is heating up; if the temperature keeps climbing it escalates to the high-condensation alarm (CSd).
Symptoms
- COH shown on the controller display as a warning
- Condenser warm and possibly dusty or restricted
- Early sign of reduced heat rejection before a full CSd alarm
- Cooling performance starting to drop
Common causes
- Condenser beginning to clog with dust or dirt
- Reduced airflow across the condenser
- High ambient temperature around the cabinet
- Condenser fan underperforming
Diagnostic steps
- 01
Confirm the warning
Read COH on the display; treat it as an early high-condensation warning that precedes the CSd alarm.
- 02
Clean the condenser
Inspect and clean the condenser per the monthly maintenance instructions to restore heat rejection before the condition worsens.
- 03
Check airflow and ambient
Ensure airflow around the unit is unobstructed and ambient temperature is within the cabinet's stated operating range.
- 04
Verify the condenser fan
Confirm the condenser fan is running so heat is being carried away from the coil.
- 05
Monitor for escalation
Watch whether COH clears after cleaning, or escalates to CSd, which indicates a more serious high-condensation condition needing service.
Keep this fix — get it by email with every Everlasting error code
A clean printable version of this Everlasting COH guide + the full Everlasting code pack (11 codes), straight to your inbox. Free.
When to call a professional
Call technical support if COH does not clear after cleaning the condenser and confirming airflow and fan operation, especially if it escalates to the CSd high-condensation alarm. The manual reserves refrigeration-circuit and condenser-fan repairs for authorized specialist personnel, so a recurring overheating warning that routine cleaning cannot resolve should be diagnosed by a technician before it damages the compressor.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Everlasting error codes
Refrigerated compartment (chamber) probe fault
Pr2Evaporator probe fault
Pr3Condenser probe fault
ALMinimum (low) temperature exceeded alarm
AHMaximum (high) temperature exceeded alarm
idOpen door / door-switch input alarm
PFPower failure alarm
CSdHigh condensation alarm
dFdDefrost timeout alarm
rtcInternal clock error