AskWhiz
08ITW Food Equipment Group

ITW Food Equipment Group 08

Booster pressure level sensor voltage below lower limit

Source: ITW FOOD EQUIPMENT GROUP/00008 EDH-EDL_EUH-EUL Dishwashers Operation and Error Card F48737 (01-23).pdf

Want this fix in your inbox? Full 08 guide + every ITW Food Equipment Group code, printable, free.

What does ITW Food Equipment Group 08 mean?

The booster pressure (water level) sensor is reporting a voltage below its allowed lower limit, so the control cannot trust its booster level reading. Cycling power to begin draining and then refilling the tank lets the pressure level sensors reset, which often clears the fault.

Symptoms

  • Error code 08 shown on the display
  • Booster water level reading appears incorrect
  • Machine will not progress through fill or rinse
  • Error persists until the sensor resets

Common causes

  • Booster pressure level sensor out of calibration or faulty
  • Loss of water or pressure at the sensor
  • Wiring or connection fault at the pressure sensor
  • Control fault reading the sensor voltage

Diagnostic steps

  1. 01

    Power off then on

    Press the power button off then on to start the draining process.

  2. 02

    Drain and refill

    Let the machine drain the tank and refill, which should reset the pressure level sensors.

  3. 03

    Confirm the sensor reads correctly

    Run a cycle and check whether the booster level reading and code 08 have cleared.

  4. 04

    Call Hobart Service if it persists

    If the error continues to display, contact Hobart Service at 1-888-4HOBART.

Keep this fix — get it by email with every ITW Food Equipment Group error code

A clean printable version of this ITW Food Equipment Group 08 guide + the full ITW Food Equipment Group code pack (21 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

Contact Hobart Service if code 08 stays on after draining and refilling to reset the pressure level sensors. A sensor reading below range may be faulty, disconnected or affected by a plumbing issue. An authorized Hobart technician should test the booster pressure level sensor and its wiring and replace it correctly so the booster water level is measured reliably.

Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.

Open a ticket — free account

Other ITW Food Equipment Group error codes