Jeros AL 03
Thermal cut-out in wash pump 1 tripped — wash pump overloaded
Source: 89000013_manual_9110_15_en.pdf
What does Jeros AL 03 mean?
AL 03 means the thermal cut-out protecting wash pump 1 has tripped because the pump was overloaded. The motor protection opens to prevent winding damage and the control raises the alarm on the operating panel. The manual's remedy is a power cycle; a recurring AL 03 is an engineer call-out.
Symptoms
- AL 03 shown on the operating panel display
- Wash pump 1 stops while the alarm is active
- Alarm returns after switching the machine OFF and ON again
Common causes
- Wash pump 1 overloaded, tripping its thermal cut-out
- Overload condition still present after a power cycle
Diagnostic steps
- 01
Switch the machine OFF and then ON again
Power-cycle the machine. This resets the control after the thermal cut-out event.
- 02
Check whether AL 03 reoccurs
If the alarm stays clear, the trip was transient; resume operation and observe the next cycle.
- 03
If AL 03 reoccurs, call an engineer
A repeating trip means wash pump 1 is genuinely overloaded — per the manual this needs an engineer, not repeated resets.
Keep this fix — get it by email with every Jeros error code
A clean printable version of this Jeros AL 03 guide + the full Jeros code pack (12 codes), straight to your inbox. Free.
When to call a professional
Call an engineer if AL 03 comes back after one power cycle — that is the manual's instruction. Repeatedly resetting an overloaded pump risks the motor; the cause of the overload has to be found at service level.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Jeros error codes
Temperature sensor in wash tank disconnected or short-circuited
AL 02Temperature sensor in rinse tank disconnected or short-circuited
AL 04Thermal cut-out in wash pump 2 tripped — machine can continue at reduced operation
AL 05Thermal cut-out in rinse pump triggered — machine can continue at reduced operation
AL 06Wash frame motor malfunction — disconnected, short-circuited or travel time exceeded
AL 07Lid contact malfunction — not switching
AL 08Lid hoist's maximum travel time exceeded
AL 09Overheating of wash water — temperature above 85°C
AL 10Overheating of rinse water — temperature above 97°C
AL 11Filling time for rinse tank exceeded
AL 13Incorrect phase sequence — reverse L1 and L2 at the main switch