Jeros AL 13
Incorrect phase sequence — reverse L1 and L2 at the main switch
Source: 89000013_manual_9110_15_en.pdf
What does Jeros AL 13 mean?
AL 13 means the phase-sequence sensor has detected the three-phase supply connected in the opposite phase sequence to the factory setting. The sensor exists to ensure the pumps turn in the right direction, so the alarm appears in the operating panel display and the machine cannot be started. The manual's fix is to swap two phases — reverse L1 and L2 of the connection cable at the main switch.
Symptoms
- AL 13 shown on the operating panel display
- Machine cannot be started while the alarm is active
- Alarm typically appears right after installation, reconnection or repair work on supply or pump cabling
Common causes
- Three-phase supply connected with the opposite phase sequence to the factory setting
- A pump cable re-fitted with the wrong phase order after repair work
Diagnostic steps
- 01
Have the supply phases swapped at the main switch
Per the manual: reverse two phases — e.g. L1 and L2 — of the connection cable at the main switch. This is mains electrical work for an authorised electrician.
- 02
Verify pump rotation direction
The manual notes arrows on the pump motors showing correct rotation: after any cable work, check the motor fan turns in the arrow's direction.
- 03
Re-check after any repair that touched a pump cable
The manual warns that a pump cable removed during repairs must be re-fitted with the correct phase sequence and the rotation re-checked.
Keep this fix — get it by email with every Jeros error code
A clean printable version of this Jeros AL 13 guide + the full Jeros code pack (12 codes), straight to your inbox. Free.
When to call a professional
AL 13's fix is at the mains connection — swapping supply phases at the main switch — and Jeros requires installation work to be done by authorised electricians. Do not open the main switch yourself; have an electrician reverse L1 and L2 and confirm pump rotation.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Jeros error codes
Temperature sensor in wash tank disconnected or short-circuited
AL 02Temperature sensor in rinse tank disconnected or short-circuited
AL 03Thermal cut-out in wash pump 1 tripped — wash pump overloaded
AL 04Thermal cut-out in wash pump 2 tripped — machine can continue at reduced operation
AL 05Thermal cut-out in rinse pump triggered — machine can continue at reduced operation
AL 06Wash frame motor malfunction — disconnected, short-circuited or travel time exceeded
AL 07Lid contact malfunction — not switching
AL 08Lid hoist's maximum travel time exceeded
AL 09Overheating of wash water — temperature above 85°C
AL 10Overheating of rinse water — temperature above 97°C
AL 11Filling time for rinse tank exceeded