Jeros AL 06
Wash frame motor malfunction — disconnected, short-circuited or travel time exceeded
Source: 89000013_manual_9110_15_en.pdf
What does Jeros AL 06 mean?
AL 06 means the wash frame motor has malfunctioned: the control detected the motor circuit disconnected or short-circuited, or the frame's minimum/maximum travel time was exceeded. The manual notes the machine can continue without the frame operating, and calls for an engineer if the alarm reoccurs.
Symptoms
- AL 06 shown on the operating panel display
- Wash frame stops operating; machine continues without it
- Frame travel takes too little or too long before the alarm appears
Common causes
- Wash frame motor circuit disconnected
- Wash frame motor short-circuited
- Frame minimum/maximum travel time exceeded
Diagnostic steps
- 01
Note that the machine can continue without the frame
Per the manual, operation may continue without the wash frame moving — plan service rather than stopping mid-shift.
- 02
Switch the machine OFF and then ON again
Power-cycle the machine to clear a transient frame-motor fault.
- 03
If AL 06 reoccurs, call an engineer
A recurring frame-motor fault (wiring or travel-time) needs service-level diagnosis per the manual.
Keep this fix — get it by email with every Jeros error code
A clean printable version of this Jeros AL 06 guide + the full Jeros code pack (12 codes), straight to your inbox. Free.
When to call a professional
The manual permits continued operation without the frame, but a recurring AL 06 is an engineer call-out. Motor-circuit faults and travel-time problems both live behind the machine's panels — authorised service territory on Jeros washers.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Jeros error codes
Temperature sensor in wash tank disconnected or short-circuited
AL 02Temperature sensor in rinse tank disconnected or short-circuited
AL 03Thermal cut-out in wash pump 1 tripped — wash pump overloaded
AL 04Thermal cut-out in wash pump 2 tripped — machine can continue at reduced operation
AL 05Thermal cut-out in rinse pump triggered — machine can continue at reduced operation
AL 07Lid contact malfunction — not switching
AL 08Lid hoist's maximum travel time exceeded
AL 09Overheating of wash water — temperature above 85°C
AL 10Overheating of rinse water — temperature above 97°C
AL 11Filling time for rinse tank exceeded
AL 13Incorrect phase sequence — reverse L1 and L2 at the main switch
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call