Randell CON Error Code
Condenser Temperature High Limit alarm on the Danfoss controller
Source: Randell/8148n-290-pcb__rd-8000-290-9000w-290-spm.pdf
What does Randell CON mean?
On a Randell prep table with the Danfoss controller, CON is the Condenser Temperature High Limit alarm. It means the condenser has reached a temperature above its allowed limit, typically because the coil is dirty or airflow is blocked, so the high side of the refrigeration system cannot reject heat properly and cooling performance drops.
Symptoms
- Display shows CON with the alarm LED lit
- Condenser coil is dirty or has objects obstructing airflow
- Machine compartment runs hot
- Cabinet has difficulty holding its set point
Common causes
- Dirty condenser coil restricting airflow
- Objects obstructing airflow through the condenser
- Inadequate ventilation or nearby heat sources
- Condenser fan not moving enough air
Ask the AskWhiz AI about Randell CON
AskWhiz
online
Diagnostic steps
Confirm the alarm
Verify the Danfoss display reads CON, the Condenser Temperature High Limit alarm.
Disconnect power before servicing
Ensure the unit is disconnected from its power source before cleaning or inspecting the condenser, per the manual.
Clean the condenser coil
The Danfoss table directs you to clean the condenser coil; brush in the direction of the fins so airflow and heat transfer are restored.
Inspect for obstructions
The table also directs inspecting the coil for any objects obstructing airflow, and removing them.
Contact service if it persists
If CON stays on after cleaning and clearing obstructions, the table directs contacting service; call 888-994-7636.
When to call a professional
Cleaning the condenser and clearing obstructions are owner tasks, but the Danfoss code table itself ends with contacting service if the alarm continues. Call a Randell Authorized Service Agent when CON persists, when the condenser fan is not running, or when a refrigeration fault is suspected. The manual requires factory-authorized service with OEM parts on these R290 units; reach service at 888-994-7636.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Randell documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Randell Error Codes
Control probe alarm on the Carel controller (air/control temperature sensor)
Defrost probe alarm on the Carel controller (evaporator/defrost temperature sensor)
Open door alarm on the Carel controller
Low temperature alarm (Carel LO / Danfoss Lo)
High temperature alarm (Carel HI / Danfoss Hi)
Dirty condenser alarm on the Carel controller
Line Voltage Too High alarm on the Danfoss controller
Line Voltage Too Low alarm on the Danfoss controller
Continuous Compressor Runtime alarm on the Danfoss controller
S1 Sensor Failure on the Danfoss controller
S2 Sensor Failure on the Danfoss controller
S3 Sensor Failure on the Danfoss controller
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call