Low temperature alarm (Carel LO / Danfoss Lo)
Source: Randell/8148n-290-pcb__rd-8000-290-9000w-290-spm.pdf
What does Randell LO mean?
On a Randell prep table, the low-temperature alarm shows as LO on the Carel controller and Lo on the Danfoss controller. It means the cabinet temperature has dropped below the controller's low-temperature alarm threshold, so the unit is running colder than intended for the rail or base it is monitoring.
Symptoms
- Display shows LO (Carel) or Lo (Danfoss) with the alarm LED lit
- Cabinet or product is colder than the desired set point
- Product near the coil may begin to freeze
- Compressor runs more than expected
Common causes
- Set point adjusted too low (incorrect set point)
- Control probe reading low or out of position
- Controller running the compressor beyond the target temperature
- Sensor fault feeding a low reading to the controller
Diagnostic steps
- 01
Confirm the low alarm
Verify the display reads LO (Carel) or Lo (Danfoss) with the alarm LED lit.
- 02
Check and adjust the set point
The manual lists an incorrect set point as a cause of a unit running too cold; adjust the control set point, changing it in small increments.
- 03
Make changes gradually
Per the manual, make set-point changes in 2-degree increments and allow the unit to operate 24 hours between adjustments.
- 04
Verify the probe position
Confirm the control probe is in place and reading correctly, since a misreading probe can drive a low alarm.
- 05
Contact service if needed
The Danfoss table directs you to contact service for the low-temperature alarm if it does not clear; call 888-994-7636.
Keep this fix — get it by email with every Randell error code
A clean printable version of this Randell LO guide + the full Randell code pack (14 codes), straight to your inbox. Free.
When to call a professional
A low-temperature alarm caused by an over-cold set point is owner-adjustable. Call a Randell Authorized Service Agent when the alarm persists after correcting the set point, when product is freezing, or when a probe or controller fault is suspected. The Danfoss code table itself directs contacting service for this alarm. All controller and refrigeration service on these R290 units must be factory-authorized; reach service at 888-994-7636.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Randell error codes
Control probe alarm on the Carel controller (air/control temperature sensor)
E1Defrost probe alarm on the Carel controller (evaporator/defrost temperature sensor)
dOrOpen door alarm on the Carel controller
HIHigh temperature alarm (Carel HI / Danfoss Hi)
CHtDirty condenser alarm on the Carel controller
CONCondenser Temperature High Limit alarm on the Danfoss controller
uHiLine Voltage Too High alarm on the Danfoss controller
uLiLine Voltage Too Low alarm on the Danfoss controller
LEAContinuous Compressor Runtime alarm on the Danfoss controller
E01S1 Sensor Failure on the Danfoss controller
E02S2 Sensor Failure on the Danfoss controller
E03S3 Sensor Failure on the Danfoss controller
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call