Low temperature alarm (Carel LO / Danfoss Lo)

Source: Randell/8148n-290-pcb__rd-8000-290-9000w-290-spm.pdf

Want this fix in your inbox? Full LO guide + every Randell code, printable, free.

What does Randell LO mean?

On a Randell prep table, the low-temperature alarm shows as LO on the Carel controller and Lo on the Danfoss controller. It means the cabinet temperature has dropped below the controller's low-temperature alarm threshold, so the unit is running colder than intended for the rail or base it is monitoring.

Symptoms

  • Display shows LO (Carel) or Lo (Danfoss) with the alarm LED lit
  • Cabinet or product is colder than the desired set point
  • Product near the coil may begin to freeze
  • Compressor runs more than expected

Common causes

  • Set point adjusted too low (incorrect set point)
  • Control probe reading low or out of position
  • Controller running the compressor beyond the target temperature
  • Sensor fault feeding a low reading to the controller

Diagnostic steps

  1. 01

    Confirm the low alarm

    Verify the display reads LO (Carel) or Lo (Danfoss) with the alarm LED lit.

  2. 02

    Check and adjust the set point

    The manual lists an incorrect set point as a cause of a unit running too cold; adjust the control set point, changing it in small increments.

  3. 03

    Make changes gradually

    Per the manual, make set-point changes in 2-degree increments and allow the unit to operate 24 hours between adjustments.

  4. 04

    Verify the probe position

    Confirm the control probe is in place and reading correctly, since a misreading probe can drive a low alarm.

  5. 05

    Contact service if needed

    The Danfoss table directs you to contact service for the low-temperature alarm if it does not clear; call 888-994-7636.

Keep this fix — get it by email with every Randell error code

A clean printable version of this Randell LO guide + the full Randell code pack (14 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

A low-temperature alarm caused by an over-cold set point is owner-adjustable. Call a Randell Authorized Service Agent when the alarm persists after correcting the set point, when product is freezing, or when a probe or controller fault is suspected. The Danfoss code table itself directs contacting service for this alarm. All controller and refrigeration service on these R290 units must be factory-authorized; reach service at 888-994-7636.

Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.

Open a ticket — free account

Other Randell error codes

AskWhiz Playground

Test your diagnostic skills

Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.

Play a real service call