Randell E02
S2 Sensor Failure on the Danfoss controller
Source: Randell/8148n-290-pcb__rd-8000-290-9000w-290-spm.pdf
What does Randell E02 mean?
On a Randell prep table with the Danfoss controller, E02 is the S2 Sensor Failure alarm. S2 is one of the controller's temperature sensors (thermistors). E02 indicates the controller cannot read a valid value from S2 because the sensor has failed, drifted out of range, or lost its connection, affecting the function that sensor controls.
Symptoms
- Display shows E02 with the alarm LED lit
- Temperature control tied to the S2 sensor is affected
- Displayed temperature may be missing or incorrect
- Defrost or cooling behavior may be abnormal
Common causes
- Failed or out-of-range S2 thermistor
- Disconnected or loose S2 sensor connector at the controller
- Damaged sensor wiring
- Controller input fault
Diagnostic steps
- 01
Confirm the alarm
Verify the Danfoss display reads E02, the S2 Sensor Failure alarm.
- 02
Disconnect power before inspecting
Ensure the unit is disconnected from its power source before checking the sensor or wiring, per the manual.
- 03
Inspect the S2 sensor connection
Check that the S2 thermistor is connected at the controller and that its wiring is not damaged or loose.
- 04
Verify cabinet temperature
Compare the displayed temperature against the set point to judge whether the unit is still holding safe temperature.
- 05
Contact service
The Danfoss table directs contacting service for a sensor failure; call 888-994-7636 to test or replace the S2 thermistor.
Keep this fix — get it by email with every Randell error code
A clean printable version of this Randell E02 guide + the full Randell code pack (14 codes), straight to your inbox. Free.
When to call a professional
The Danfoss code table directs contacting service for an S2 sensor failure. Identifying which thermistor is at fault and replacing it with the correct OEM part is service-technician work, and the manual requires factory-authorized service with OEM parts on these R290 units. Call a Randell Authorized Service Agent at 888-994-7636 if E02 does not clear after checking the connection.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Randell error codes
Control probe alarm on the Carel controller (air/control temperature sensor)
E1Defrost probe alarm on the Carel controller (evaporator/defrost temperature sensor)
dOrOpen door alarm on the Carel controller
LOLow temperature alarm (Carel LO / Danfoss Lo)
HIHigh temperature alarm (Carel HI / Danfoss Hi)
CHtDirty condenser alarm on the Carel controller
CONCondenser Temperature High Limit alarm on the Danfoss controller
uHiLine Voltage Too High alarm on the Danfoss controller
uLiLine Voltage Too Low alarm on the Danfoss controller
LEAContinuous Compressor Runtime alarm on the Danfoss controller
E01S1 Sensor Failure on the Danfoss controller
E03S3 Sensor Failure on the Danfoss controller
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call