Randell uLi
Line Voltage Too Low alarm on the Danfoss controller
Source: Randell/8148n-290-pcb__rd-8000-290-9000w-290-spm.pdf
What does Randell uLi mean?
On a Randell prep table with the Danfoss controller, uLi is the Line Voltage Too Low alarm. The controller monitors supply voltage and alarms when incoming line voltage drops below its acceptable range. The manual notes the Danfoss controller has low-voltage protection and will not output to the compressor when voltage is below 104V, so low voltage stops cooling.
Symptoms
- Display shows uLi with the alarm LED lit
- Compressor does not run or does not start
- Cabinet temperature rises while the alarm is active
- Lights or other loads on the same circuit may dim
Common causes
- Incoming line voltage below the unit's rated range (under 104V)
- Voltage drop from an overloaded or shared circuit
- Long or undersized supply wiring
- Building power supply problem
Diagnostic steps
- 01
Confirm the alarm
Verify the Danfoss display reads uLi, the Line Voltage Too Low alarm.
- 02
Verify the power source voltage
The Danfoss table directs verifying the voltage of the power source; the manual specifies this reading be performed by a qualified technician.
- 03
Check the dedicated circuit
Confirm the unit is on its own dedicated line, as the manual requires, so other loads are not dragging the voltage down.
- 04
Understand the protection cutout
Recall that the Danfoss controller will not output to the compressor below 104V, so cooling stays off until the voltage recovers.
- 05
Contact service
The table directs contacting service for this alarm; call 888-994-7636 once a low-voltage condition is confirmed.
Keep this fix — get it by email with every Randell error code
A clean printable version of this Randell uLi guide + the full Randell code pack (14 codes), straight to your inbox. Free.
When to call a professional
Measuring supply voltage must be done by a qualified technician per the Danfoss table and the manual's warnings. Call a qualified electrician or a Randell Authorized Service Agent to confirm and correct low line voltage, since sustained low or high voltage can detrimentally affect operation and void warranty. Do not attempt live electrical readings yourself; reach service at 888-994-7636.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Randell error codes
Control probe alarm on the Carel controller (air/control temperature sensor)
E1Defrost probe alarm on the Carel controller (evaporator/defrost temperature sensor)
dOrOpen door alarm on the Carel controller
LOLow temperature alarm (Carel LO / Danfoss Lo)
HIHigh temperature alarm (Carel HI / Danfoss Hi)
CHtDirty condenser alarm on the Carel controller
CONCondenser Temperature High Limit alarm on the Danfoss controller
uHiLine Voltage Too High alarm on the Danfoss controller
LEAContinuous Compressor Runtime alarm on the Danfoss controller
E01S1 Sensor Failure on the Danfoss controller
E02S2 Sensor Failure on the Danfoss controller
E03S3 Sensor Failure on the Danfoss controller
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call