Traulsen System Leak Alarm
The Intela-Traul control detects a refrigeration system leak based on discharge-line temperature behavior.
Source: TRAULSEN/00051 INTELA-TRAUL Controls Serv Man TR35705 (10-04).pdf
What does Traulsen System Leak Alarm mean?
The system leak alarm fires when the discharge line temperature does not rise as expected during a refrigeration cycle, which the control interprets as a possible refrigerant leak or low charge. It uses the discharge-line sensor to judge whether the sealed system is performing normally, so a misplaced or failed discharge sensor can also raise this alarm.
Symptoms
- Alarm LED illuminated and horn sounding on the control
- Discharge temperature not rising about 45F within the expected cycle window
- Cabinet not holding temperature
- Compressor running with poor cooling
Common causes
- Low refrigerant charge in the system
- Discharge line sensor not properly connected
- Failed discharge line sensor
- Dislocated discharge sensor probe out of correct position
Diagnostic steps
- 01
Check refrigerant charge
Check the compressor for low refrigerant; add refrigerant if the charge is not OK.
- 02
Inspect the discharge line sensor
Check the discharge line sensor per the manual procedure and replace it if it is failed.
- 03
Confirm probe connections
Verify the sensor probes are properly connected and reconnect any that are loose.
- 04
Verify probe placement
Check for a dislocated sensor probe and relocate it to the correct position on the hot-gas side near the compressor.
- 05
Re-insulate the discharge sensor
Ensure the discharge sensor is properly placed before the hot-gas loop and insulated as required.
Keep this fix — get it by email with every Traulsen error code
A clean printable version of this Traulsen System Leak Alarm guide + the full Traulsen code pack (11 codes), straight to your inbox. Free.
When to call a professional
Call a refrigeration technician for a system leak alarm. Diagnosing low charge, locating a refrigerant leak, and recharging the sealed system require EPA certification, recovery equipment, and leak-detection tools. Relocating or replacing the discharge-line sensor and confirming proper placement near the compressor are service tasks; improper handling can mask a real leak and damage the compressor.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Traulsen error codes
Cabinet temperature has risen above the high-temperature alarm setpoint on the Intela-Traul control.
Low Temperature AlarmCabinet temperature has dropped below the low-temperature alarm setpoint on the Intela-Traul control.
Door Open AlarmThe Intela-Traul control detects a cabinet door open longer than the allowed time.
Power Loss AlarmThe Intela-Traul control detected an interruption of power to the unit.
CondenserClean AlarmThe Intela-Traul control signals that the condenser coil needs cleaning or that condenser airflow is restricted.
Cabinet Sensor Open or ShortedThe Intela-Traul control reads the cabinet air sensor as open or shorted.
Coil Sensor Open or ShortedThe Intela-Traul control reads the evaporator coil sensor as open or shorted.
Discharge Line Sensor Open or ShortedThe Intela-Traul control reads the discharge line sensor as open or shorted.
Liquid Line Sensor Open or ShortedThe Intela-Traul control reads the liquid line sensor as open or shorted.
Defrost Termination by TimeDefrost has terminated by time rather than by temperature for 72 hours on the Intela-Traul control.